Maltron BioScan 916

The Assessment of Human Body Composition in determining the nutritional status and fluid monitoring of individuals or a population is an important factor in which Maltron Analyzers are indispensable measuring tools.
 

BioScan 916 Image
"High Speed Medically isolated USB interface"

  BioScan 916  RESULTS DISPLAYED  
Impedance Total Body POTASSIUM Target Water (min / max) %
Phase Angle Total Body Calcium Mass Extra cellular Fluid
Resistance Glomerular Filtration Rate Extra cellular Water Volume
Reactance Creatinine Intercellular Water Volume
Capacitance Body Volume Total Body Water Volume
Dry Weight Fat % Extra cellular Water %
Body Cell Mass Fat Mass Intercellular Water %
Extra cellular Mass Fat Free Mass Total Body Water %
Protein Mass Fat Free Mass % Extra cellular /
Intracellular Water
Mineral Mass Body Mass Index Interstitial-Fluid Extra vascular
Muscle Mass Rest Metabolic Rate Plasma-fluid (Intravascular)
Glycogen Mass Target Fat (Min / max) %    
BODY DENSITY Target Weight (min / max)    
 
   BioScan 916 in Clinical & Medical Applications   
Fluid retention
Medical Research
Assessing malnutrition
Dry weight assessment
Epidemiologic field studies
Monitoring Patient recovery
Monitoring Diabetes Patients
Monitoring the effects of drugs
Estimation of Body Composition
Monitoring effectives of weight loss
Effects of Hydration and dehydration
Eating disorders and effects of fasting
Body Composition assessment in elderly
Assessing patients with medical condition
Bedside Diagnostic & Monitoring of Patients
Assessment of over weight and obese patients
Body Composition assessment during pregnancy
Estimation of Total Body Water, Extra/Intracellular Water
Hormone replacement therapy in postmenopausal women
Monitoring Dialysis & Burns patients receiving fluid therapy
Monitoring of body Fluid in patients before and after surgery
Cystic Fibrosis patients can monitored for effects of medications
Planning fluid balance in cardiac, paediatric, neonatal and hepatic patient and those in Intensive care units
 
    MANY MORE ADVANTAGES  
Portable Semi Auto Recalibration check
Non-invasive Automatic switch off
No undressing Quick, Safe and Easy
Pre-calibration No Computer Required
Highly accurate Automatic Data Storage
Metric / Imperial Displays results and Targets
Battery operated USB Fast Data Transfer
Data Storage No assistance or technical knowledge required

BioScan, an indispensable measuring instrument in the field of Medical  Science

BioScan a practical, non-invasive, non-intrusive, highly accurate portable diagnostic monitoring system for assessing Body Composition, Nutritional, Fluid monitoring in both health and clinical patients.

Calibrated for all age groups including different nationality. BioScan is a simple highly accurate system, that uses the entered data and the raw data measured to provide a complete clinical analysis displaying over 35 patients parameters within a few seconds. This information is provided without the need of complex clinical techniques like radioisotope dilution.


Additionally features of the BioScan is its ability to measure and store hundreds of patient data which can be later down loaded into a PC via a high-speed USB interface.

BioScan uses scientific patented method of measuring Electrical Impedance. A total of four electrodes are used (tetrapolar). 2 electrodes are applied to the hand and two to the foot. A low-level battery operated electric current is passed through the body and
the Impedance, Phase, Resistance and Reactance are measured.

Although the principal of electrical Impedance has been well established, it is the Phase sensitive instrumentation like the BioScan that has increased considerable interest in the estimation of Body Composition in the field of Human Nutrition, Human Biology, Physiology and Sports Medicines.

BioScan combines the power of modern electronics and proprietary digital signal processing to compute physical modelling of biological tissues. BioScan allows the estimation of many parameters, including Total Body Water (TBW), Intercellular Water (ICW), Extracellular Water (ECW), Fat Free Mass (FFM), Fat Mass (FM), Body Cell Mass (BCM) and Dry Weight.

    BioScan Range Comparison of Different Models 
 

BioScan 916 Technical

BioScan 920 Technical

BioScan 920-2 Technical

50kHz

5kHz, 50kHz, 100kHz, 200kHz

5kHz, 50kHz, 100kHz, 200kHz

Single frequency

Multi- frequency

Multi- frequency

-

-

Multi- mode configurable

1channel - 4 point

1channel -  4 point

2 channel - 8 point

-

Single point Segmental

Single/Multi point segmental

-

Single point configurable

Single/Multi point configurable

One side whole body

One side whole body

One side whole body

-

-

Both side whole body

 

Thorax

Thorax

-

Trunk

Trunk

-

Single Arms Segmental

Single/Multi point Arms Segmental

-

Single point Legs Segmental

Single/Multi point Leg Segmental

-

Single point Trunk Segmental

Single/Multi point Trunk Segmental

-

Single point Thorax Segmental

Single/Multi point Thorax Segmental

-

-

Both side whole body Data 5kHz, 50kHz, 100kHz, 200kHz

-

Thorax Data 5kHz, 50kHz, 100kHz, 200kHz

Thorax Data 5kHz, 50kHz, 100kHz, 200kHz

-

Single point Thorax Data 5kHz, 50kHz, 100kHz, 200kHz

Multi point Thorax Data 5kHz, 50kHz, 100kHz, 200kHz

-

Arms Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

Multi point Arms Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

-

Legs Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

Multi point Leg Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

-

Trunk Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

Multi point Trunk Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

-

Data 5kHz, 50kHz, 100kHz, 200kHz

Data 5kHz, 50kHz, 100kHz, 200kHz

-

Single Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

Multi segmental Data 5kHz, 50kHz, 100kHz, 200kHz

-

Single point configurable Data 5kHz, 50kHz, 100kHz, 200kHz

Multi point configurable Data 5kHz, 50kHz, 100kHz, 200kHz

AA Batteries

Rechargeable Batteries

Rechargeable Batteries

-

Universal global charger

Universal global charger

Single Line LCD

Blue large Back light LCD

Blue large Back light LCD

Capacitance

Capacitance

Capacitance

Dry Weight

Dry Weight

Dry Weight

Fat %

Fat %

Fat %

Fat Mass

Fat Mass

Fat Mass

Fat Free Mass

Fat Free Mass

Fat Free Mass

Fat Free Mass %

Fat Free Mass %

Fat Free Mass %

Body Volume

Body Volume

Body Volume

Body Density

Body Density

Body Density

Body Mass Index

Body Mass Index

Body Mass Index

Resting Metabolic Rate

Resting Metabolic Rate

Resting Metabolic Rate

Target Fat (min/max)%

Target Fat (min/max)%

Target Fat (min/max)%

Target Weight (min/max)

Target Weight (min/max)

Target Weight (min/max)

Target Water (min/max)%

Target Water (min/max)%

Target Water (min/max)%

Glomerular Filtration Rate

Glomerular Filtration Rate

Glomerular Filtration Rate

Total Body Potassium

Total Body Potassium

Total Body Potassium

Total Body Calcium

Total Body Calcium

Total Body Calcium

Protein Mass

Protein Mass

Protein Mass

Mineral Mass

Mineral Mass

Mineral Mass

Glycogen Mass

Glycogen Mass

Glycogen Mass

Extracellular Fluid

Extracellular Fluid

Extracellular Fluid

Intracellular Water Volume

Intracellular Water Volume

Intracellular Water Volume

Extracellular Water Volume

Extracellular Water Volume

Extracellular Water Volume

Extracellular Water Lt

Extracellular Water Lt

Extracellular Water Lt

Total Body Water Volume

Total Body Water Volume

Total Body Water Volume

Intracellular Water Lt

Intracellular Water Lt

Intracellular Water Lt

Intracellular Water %

Intracellular Water %

Intracellular Water %

Extracellular Water %

Extracellular Water %

Extracellular Water %

Total Body Water Lt

Total Body Water Lt

Total Body Water Lt

Total Body Water %

Total Body Water %

Total Body Water %

Extracellular Mass

Extracellular Mass

Extracellular Mass

Extracellular Solids

Extracellular Solids

Extracellular Solids

Extracellular /
Intracellular Water

Extracellular /
Intracellular Water

Extracellular /
Intracellular Water

Extracellular Water / Total

Extracellular Water / Total

Extracellular Water / Total

Body Water

Body Water

Body Water

Intracellular Water / Total

Intracellular Water / Total

Intracellular Water / Total

Body Water

Body Water

Body Water

Interstitial-Fluid Extravascular

Interstitial-Fluid Extravascular

Interstitial-Fluid Extravascular

Plasma-Fluid (Intravascular)

Plasma-Fluid (Intravascular)

Plasma-Fluid (Intravascular)

Creatinine

Creatinine

Creatinine

Body Cell Mass

Body Cell Mass

Body Cell Mass

Muscle Mass

Muscle Mass

Muscle Mass

   
   TECHNICAL SPECIFICATIONS  
   Technique    Bio-electrical Impedance Analyzer

BioScan 916 Contents Image

CONTENTS
BioScan 916 Analyzer
Maltron Electrode Cables
Maltron Electrodes
Batteries
Operating Manual
High Impact Carrying Case
   Frequency    50Khz Impedance, Phase, Resistance, Reactance
   Resolution    Measures in increments of 0.1%
   Impedance Range    100 -1000 Ohms
   Resolution    1 Ohm
   Accuracy    Impedance to within 0.5% + / - 3Ω across 300 - 1000Ω
   Phase range    1.5 - 30.0 Degree
   Resolution    0.1 Degree
   Accuracy    + / - 0.1 Degree across 1.5 - 15 Degrees
   + / - 0.2 Degree across 15 - 30 Degrees
   Resistance range    100R - 1000R
   Resolution    1 Ohms
   Reactance Range    8R - 200R
   Resolution    0.1 Ohms
   BioScan 916    Data Output Resolution
   TBW - ECW - ICW in increments of 0.1 litres (0.1pints)
   Estimation of    FFM - FM in increments of 0.1Kg (0.1 lbs)
   BCM 0.1Kg (0.1 lb)
   Ambient Temperature Environment    +10oc to 40oc
   Relative Humidity    30% to 75% non-condensing
   Atmospheric Pressure    700hPa to 1060hPa
   Test Current    0.7mA
   Power    4 x 1.5AA Batteries IEC No. LR6
   Battery Current    50mA (approx)
    Weight    .575 kgs (1.268 lbs) with batteries
   .450 kgs (0.992 lbs) without batteries & battery
   Compartment
   Dimensions    266 x 90/144 x 60 mm
   Service    No serviceable parts other than replacement of battery
   Guarantee    12 months parts and labour (excluding disposables)

This page is from maltronint.com