BioScan, an indispensable measuring instrument
in the field of Medical
Science |
The BioScan 920
Multi-frequency Analyser with its unique features is a
rapid, non-invasive, inexpensive method for evaluating
hydration and nutrition status. The use of Maltron Analysers
as excellent estimators continues to increase in the global
field of Medical Science.
The advance
circuitry and processing power of the BioScan 920 allows it
to measure Extracellular (ECF) and Intracellular Fluid (ICF)
volume without the need of complex clinical techniques like
radioisotope dilution. In addition to estimating the
standard parameters this advanced system is the worldís
first to provide estimation of mineral content.
All data is
recorded and displayed immediately for analysis by the
system. Results can be viewed on the large graphic LCD
display or downloaded via PC to the software for analysis. The graphic Bar Chart displays the % of
Extracellular and Intracellular water.
Maltron's state
of the art circuitry allows you to monitor fluid changes and
shift in whole body, thorax, trunk, legs and arms.
At various
frequencies biological tissues act as conductors or
insulators and current applied will follow a path of least
resistance. This is because Fat Free Mass (FFM) which
contains large amounts of water (73%) and electrolytes are
good conductors of electrical current than Fat Mass (FM).
Current passes through Extracellular fluid at low
frequencies and at higher it penetrates cell membranes
passing through both Intracellular and Extracellular fluid.
Fat Mass contains very little water and is a poor conductor
of electrical current.
Water, the most
abundant element of the body, accounts for almost 50-60% of
an adults body weight. The total body water is divided into
Intracellular Fluid (ICF) and Extracellular Fluid (ECF).
Intracellular fluid is found within the cell mass of the
body and Extracellular is outside the cells. The make up of
the ECF includes interstitial fluid, blood plasma,
cerebrospinal fluid, intraocular fluid and gastrointestinal
fluid.
ICF and ECF
compartments in a healthy individual are highly regulated.
In disease conditions excess fluid accumulation occurs in
the Extracellular spaces.
The parameters
measured by the BioScan 920 provide assessment of clinical
and nutritional status helping detect abnormal conditions.
|
| BioScan
Range Comparison of Different Models |
|
|
|
BioScan 916 Technical |
BioScan 920 Technical |
BioScan 920-2 Technical
|
|
50kHz |
5kHz, 50kHz,
100kHz, 200kHz |
5kHz, 50kHz,
100kHz, 200kHz |
|
Single frequency |
Multi- frequency |
Multi- frequency |
|
- |
- |
Multi- mode configurable |
|
1channel - 4 point |
1channel - 4 point |
2 channel - 8 point |
|
- |
Single point Segmental
|
Single/Multi point segmental |
|
- |
Single point configurable |
Single/Multi point configurable |
|
One side whole
body |
One side whole
body |
One side whole
body |
|
- |
- |
Both side whole
body |
|
|
Thorax |
Thorax |
|
- |
Trunk |
Trunk |
|
- |
Single Arms Segmental |
Single/Multi point Arms Segmental |
|
- |
Single point Legs Segmental |
Single/Multi point Leg Segmental |
|
- |
Single point Trunk Segmental |
Single/Multi point Trunk Segmental |
|
- |
Single point Thorax Segmental |
Single/Multi point Thorax Segmental |
|
- |
- |
Both side whole body Data 5kHz,
50kHz, 100kHz, 200kHz |
|
- |
Thorax
Data 5kHz, 50kHz, 100kHz, 200kHz |
Thorax
Data 5kHz, 50kHz, 100kHz, 200kHz |
|
- |
Single point Thorax
Data 5kHz, 50kHz, 100kHz, 200kHz |
Multi
point Thorax
Data 5kHz, 50kHz, 100kHz, 200kHz |
|
- |
Arms
Segmental
Data 5kHz, 50kHz, 100kHz, 200kHz |
Multi
point Arms Segmental
Data 5kHz, 50kHz, 100kHz, 200kHz |
|
- |
Legs
Segmental
Data 5kHz, 50kHz, 100kHz, 200kHz |
Multi
point Leg Segmental
Data 5kHz, 50kHz, 100kHz, 200kHz |
|
- |
Trunk
Segmental
Data 5kHz, 50kHz, 100kHz, 200kHz |
Multi
point Trunk Segmental
Data 5kHz, 50kHz, 100kHz, 200kHz |
|
- |
Data 5kHz, 50kHz, 100kHz, 200kHz |
Data 5kHz, 50kHz, 100kHz, 200kHz |
|
- |
Single Segmental
Data 5kHz, 50kHz, 100kHz, 200kHz |
Multi segmental
Data
5kHz, 50kHz, 100kHz, 200kHz |
|
- |
Single point configurable
Data 5kHz, 50kHz, 100kHz, 200kHz |
Multi
point configurable
Data 5kHz, 50kHz, 100kHz, 200kHz |
|
AA Batteries |
Rechargeable Batteries |
Rechargeable Batteries |
|
- |
Universal global charger |
Universal global charger |
|
Single Line LCD |
Blue large Back light LCD |
Blue large Back light LCD |
|
Capacitance |
Capacitance |
Capacitance |
|
Dry Weight |
Dry Weight |
Dry Weight |
|
Fat % |
Fat % |
Fat % |
|
Fat Mass |
Fat Mass |
Fat Mass |
|
Fat Free Mass |
Fat Free Mass |
Fat Free Mass |
|
Fat Free Mass % |
Fat Free Mass % |
Fat Free Mass % |
|
Body Volume |
Body Volume |
Body Volume |
|
Body Density |
Body Density |
Body Density |
|
Body Mass Index |
Body Mass Index |
Body Mass Index |
|
Resting Metabolic
Rate |
Resting Metabolic
Rate |
Resting Metabolic
Rate |
|
Target Fat (min/max)% |
Target Fat (min/max)% |
Target Fat (min/max)% |
|
Target Weight (min/max) |
Target Weight (min/max) |
Target Weight (min/max) |
|
Target Water (min/max)% |
Target Water (min/max)% |
Target Water (min/max)% |
|
Glomerular
Filtration Rate |
Glomerular
Filtration Rate |
Glomerular
Filtration Rate |
|
Total Body
Potassium |
Total Body
Potassium |
Total Body
Potassium |
|
Total Body Calcium |
Total Body Calcium |
Total Body Calcium |
|
Protein Mass |
Protein Mass |
Protein Mass |
|
Mineral Mass |
Mineral Mass |
Mineral Mass |
|
Glycogen Mass |
Glycogen Mass |
Glycogen Mass |
|
Extracellular
Fluid |
Extracellular
Fluid |
Extracellular
Fluid |
|
Intracellu | | |