Maltron BioScan 920-2

The Assessment of Human Body Composition in determining the nutritional status and fluid monitoring of individuals or a population is an important factor in which Maltron Analyzers are indispensable measuring tools.
 

"High Speed Medically isolated USB and Bluetooth interface"

  BioScan 920-2  RESULTS DISPLAYED  
Impedance Total Body POTASSIUM Target Water (min / max) %
Phase Angle Total Body Calcium Mass Extra cellular Fluid
Resistance Glomerular Filtration Rate Extra cellular Water Volume
Reactance Creatinine Intercellular Water Volume
Capacitance Body Volume Total Body Water Volume
Dry Weight Fat % Extra cellular Water %
Body Cell Mass Fat Mass Intercellular Water %
Extra cellular Mass Fat Free Mass Total Body Water %
Protein Mass Fat Free Mass %
 
Extra cellular /
Intracellular Water
Mineral Mass Body Mass Index Interstitial-Fluid Extra vascular
Muscle Mass Rest Metabolic Rate Plasma-fluid (Intravascular)
Glycogen Mass Target Fat (Min / max) %    
BODY DENSITY Target Weight (min / max)    
 
   BioScan 920-2 in Clinical & Medical Applications   
Fluid retention
Medical Research
Assessing malnutrition
Dry weight assessment
Epidemiologic field studies
Monitoring Patient recovery
Monitoring Diabetes Patients
Monitoring the effects of drugs
Estimation of Body Composition
Monitoring effectives of weight loss
Effects of Hydration and dehydration
Eating disorders and effects of fasting
Body Composition assessment in elderly
Assessing patients with medical condition
Bedside Diagnostic & Monitoring of Patients
Assessment of over weight and obese patients
Body Composition assessment during pregnancy
Estimation of Total Body Water, Extra/Intracellular Water
Hormone replacement therapy in postmenopausal women
Monitoring Dialysis & Burns patients receiving fluid therapy
Monitoring of body Fluid in patients before and after surgery
Cystic Fibrosis patients can monitored for effects of medications
Planning fluid balance in cardiac, paediatric, neonatal and hepatic patient and those in Intensive care units
 
    MANY MORE ADVANTAGES  
Portable Semi Auto Recalibration check
Non-invasive Automatic switch off
No undressing Quick, Safe and Easy
Pre-calibration No Computer Required
Highly accurate Automatic Data Storage
Metric / Imperial Displays results and Targets
Battery operated USB Fast Data Transfer
Data Storage
 
No assistance or technical knowledge required

   EXAMPLES OF DIFFERENT CONFIGURATIONS 

BioScan, an indispensable measuring instrument in the field of Medical Science

The BioScan 920-2 Multi-frequency Analyser with its unique features is a rapid, non-invasive, inexpensive method for evaluating hydration and nutrition status. The use of Maltron Analysers as excellent estimators continues to increase in the global field of Medical Science.

The advance circuitry and processing power of the BioScan 920-2 allows it to measure Extracellular (ECF) and Intracellular Fluid (ICF) volume without the need of complex clinical techniques like radioisotope dilution. In addition to estimating the standard parameters this advanced system is the worldís first to provide estimation of mineral content.

All data is recorded and displayed immediately for analysis by the system. Results can be viewed on the large graphic LCD display or downloaded via PC to the software for analysis. The graphic Bar Chart displays the % of Extracellular and Intracellular water.

Maltron's state of the art circuitry allows you to monitor fluid changes and shift in whole body, thorax, trunk, legs and arms.

At various frequencies biological tissues act as conductors or insulators and current applied will follow a path of least resistance. This is because Fat Free Mass (FFM) which contains large amounts of water (73%) and electrolytes are good conductors of electrical current than Fat Mass (FM). Current passes through Extracellular fluid at low frequencies and at higher it penetrates cell membranes passing through both Intracellular and Extracellular fluid. Fat Mass contains very little water and is a poor conductor of electrical current.

Water, the most abundant element of the body, accounts for almost 50-60% of an adults body weight. The total body water is divided into Intracellular Fluid (ICF) and Extracellular Fluid (ECF). Intracellular fluid is found within the cell mass of the body and Extracellular is outside the cells. The make up of the ECF includes interstitial fluid, blood plasma, cerebrospinal fluid, intraocular fluid and gastrointestinal fluid.

ICF and ECF compartments in a healthy individual are highly regulated. In disease conditions excess fluid accumulation occurs in the Extracellular spaces.

The parameters measured by the BioScan 920-2 provide assessment of clinical and nutritional status helping detect abnormal conditions.

    BioScan Range Comparison of Different Models 

BioScan 916 Technical

BioScan 920 Technical

BioScan 920-2 Technical

50kHz

5kHz, 50kHz, 100kHz, 200kHz

5kHz, 50kHz, 100kHz, 200kHz

Single frequency

Multi- frequency

Multi- frequency

-

-

Multi- mode configurable

1channel - 4 point

1channel -  4 point

2 channel - 8 point

-

Single point Segmental

Single/Multi point segmental

-

Single point configurable

Single/Multi point configurable

One side whole body

One side whole body

One side whole body

-

-

Both side whole body

 

Thorax

Thorax

-

Trunk

Trunk

-

Single Arms Segmental

Single/Multi point Arms Segmental

-

Single point Legs Segmental

Single/Multi point Leg Segmental

-

Single point Trunk Segmental

Single/Multi point Trunk Segmental

-

Single point Thorax Segmental

Single/Multi point Thorax Segmental

-

-

Both side whole body Data 5kHz, 50kHz, 100kHz, 200kHz

-

Thorax Data 5kHz, 50kHz, 100kHz, 200kHz

Thorax Data 5kHz, 50kHz, 100kHz, 200kHz

-

Single point Thorax Data 5kHz, 50kHz, 100kHz, 200kHz

Multi point Thorax Data 5kHz, 50kHz, 100kHz, 200kHz

-

Arms Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

Multi point Arms Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

-

Legs Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

Multi point Leg Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

-

Trunk Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

Multi point Trunk Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

-

Data 5kHz, 50kHz, 100kHz, 200kHz

Data 5kHz, 50kHz, 100kHz, 200kHz

-

Single Segmental Data 5kHz, 50kHz, 100kHz, 200kHz

Multi segmental Data 5kHz, 50kHz, 100kHz, 200kHz

-

Single point configurable Data 5kHz, 50kHz, 100kHz, 200kHz

Multi point configurable Data 5kHz, 50kHz, 100kHz, 200kHz

AA Batteries

Rechargeable Batteries

Rechargeable Batteries

-

Universal global charger

Universal global charger

Single Line LCD

Blue large Back light LCD

Blue large Back light LCD

Capacitance

Capacitance

Capacitance

Dry Weight

Dry Weight

Dry Weight

Fat %

Fat %

Fat %

Fat Mass

Fat Mass

Fat Mass

Fat Free Mass

Fat Free Mass

Fat Free Mass

Fat Free Mass %

Fat Free Mass %

Fat Free Mass %

Body Volume

Body Volume

Body Volume

Body Density

Body Density

Body Density

Body Mass Index

Body Mass Index

Body Mass Index

Resting Metabolic Rate

Resting Metabolic Rate

Resting Metabolic Rate

Target Fat (min/max)%

Target Fat (min/max)%

Target Fat (min/max)%

Target Weight (min/max)

Target Weight (min/max)

Target Weight (min/max)

Target Water (min/max)%

Target Water (min/max)%

Target Water (min/max)%

Glomerular Filtration Rate

Glomerular Filtration Rate

Glomerular Filtration Rate

Total Body Potassium

Total Body Potassium

Total Body Potassium

Total Body Calcium

Total Body Calcium

Total Body Calcium

Protein Mass

Protein Mass

Protein Mass

Mineral Mass

Mineral Mass

Mineral Mass

Glycogen Mass

Glycogen Mass

Glycogen Mass

Extracellular Fluid

Extracellular Fluid

Extracellular Fluid

Intracellular Water Volume

Intracellular Water Volume

Intracellular Water Volume

Extracellular Water Volume

Extracellular Water Volume

Extracellular Water Volume

Extracellular Water Lt

Extracellular Water Lt

Extracellular Water Lt

Total Body Water Volume

Total Body Water Volume

Total Body Water Volume

Intracellular Water Lt

Intracellular Water Lt

Intracellular Water Lt

Intracellular Water %

Intracellular Water %

Intracellular Water %

Extracellular Water %

Extracellular Water %

Extracellular Water %

Total Body Water Lt

Total Body Water Lt

Total Body Water Lt

Total Body Water %

Total Body Water %

Total Body Water %

Extracellular Mass

Extracellular Mass

Extracellular Mass

Extracellular Solids

Extracellular Solids

Extracellular Solids

Extracellular /
Intracellular Water

Extracellular /
Intracellular Water

Extracellular /
Intracellular Water

Extracellular Water / Total

Extracellular Water / Total

Extracellular Water / Total

Body Water

Body Water

Body Water

Intracellular Water / Total

Intracellular Water / Total

Intracellular Water / Total

Body Water

Body Water

Body Water

Interstitial-Fluid Extravascular

Interstitial-Fluid Extravascular

Interstitial-Fluid Extravascular

Plasma-Fluid (Intravascular)

Plasma-Fluid (Intravascular)

Plasma-Fluid (Intravascular)

Creatinine

Creatinine

Creatinine

Body Cell Mass

Body Cell Mass

Body Cell Mass

Muscle Mass

Muscle Mass

Muscle Mass

 

 

   TECHNICAL SPECIFICATIONS  
   Technique    Bio-electrical Impedance Analyzer

CONTENTS
BioScan 920-2 Analyzer
Maltron Electrode Cables
USB Download Cable
Maltron Electrodes
Medical Power Pack
Operating Manual
High Impact Carrying Case
   Frequency    Multi-frequency (5kHz, 50kHz, 100kHz, 200kHz)
   Impedance Range    5 - 1100 Ohms
   Impedance Resolution    100 - 1100R range : 1R
   Impedance Accuracy    Impedance to within 0.5% of F.S.D. +/- 3R
   across 5 - 1100 R range
   Phase range    1 - 30.0 Degree
   Phase Resolution    0.05 Degree
   Phase Accuracy    1% of F.S.D. +/- 0.1 Degree
   Resistance Range    5 - 100R
   Resistance Resolution

   5 - 100R range : 0.1R
   100 - 1100R range : 1R

   Reactance Range    0R - 580R
   Reactance Resolution    0.1 Ohms  
 

   BioScan 916 Estimation of  


 

   Ambient Temperature Environment
   Relative Humidity
   Atmospheric Pressure
   Test Current
   Power
   Battery Current
   Weight
   Dimensions
   Service
   Guarantee

  

   DATA OUTPUT RESOLUTION
  
TBW - ECW - ICW in increments of 0.1 litres (0.1pints)
  
FFM - FM in increments of 0.1Kg (0.1lbs)
   BCM 0.1Kg (0.1lb)

   +10oc to 40oc
   30% to 75% non-condensing
   700hPa to 1060hPa
   0.8mA

   Mains adapter or 4 X NiMH rechargeable cells
   1.825 kgs
   272 x 302 x 130 mm
  (10.7 x 11.9 x 5.1ins)

   No serviceable parts other than replacement of battery
   12 months parts and labour (excluding disposables)

 

This page is from maltronint.com